NexSys v. 3.0 Crest Audio Inc.
Page 15.4 Software Manual
Curve Names
When initiating a new test curve you will be prompted to enter a name for that curve. If you
do not enter a name the date and time of the curve will be automatically entered. All saved
curves will be listed chronologically in the history box just below the grid.
Double clicking the left mouse button on any of these stored curves will open that test and
will display the curve on the grid. Multiple curves may be opened at one time. Opening
curves in the order in which they were recorded allows you to determine if they are migrat-
ing in a particular direction which may be an indicator of a weakening driver and potential
failure.